Search results for "Rotation system"

showing 1 items of 1 documents

Operation of the MAMI accelerator with a Wien filter based spin rotation system

2006

A compact spin rotation system based on a Wien filter has been installed at the Mainz microtron accelerator (MAMI). Under operation with varying spin rotation angles a significant change of focal length together with a shift of the central beam trajectory is expected. We demonstrate that these effects can be kept under control. As a consequence operation with spin rotation angles between 0° and ±90° has been achieved without compromising the beam quality and operational stability of MAMI.

PhysicsNuclear and High Energy PhysicsWien filterRotationNuclear physicsRotation systemBeam trajectoryPhysics::Accelerator PhysicsFocal lengthLaser beam qualityNuclear ExperimentSpin (physics)InstrumentationMicrotronNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct